Re: ONTAP 8.3 Aggregate and volumes destroyed. Need to recover data.
Hello, Have you try to do it in maintenance mode? I should have a 8.3 in my lab, I will check if i found something.
View ArticleRe: storage takeover
Hello, You can get the event log from that day and check if there is any information about the reboot.
View ArticleRe: ONTAP 8.3 Aggregate and volumes destroyed. Need to recover data.
Thanks for your reply, GMox.I didn't tried yet. I have a chance to try it in short time (this Fri), and let you know what happen
View ArticleRe: Brocade warm reboot
Well, it's not about having two fabrics. According to the FOS Upgrade Guide, the warm reboot is nondisruptive. Only Generic Services are affected, so the switch will not be able to register a new...
View ArticleRe: ONTAP 8.3 Aggregate and volumes destroyed. Need to recover data.
Hello Xsalvia,Protection against accidental volume deletionStarting with Data ONTAP 8.3, new default functionality is available to aid in the recovery ofaccidentally deleted FlexVol volumes.After all...
View ArticleRe: storage takeover
Hello Weiliu,Gmox is right, you need to download the SP/BMC logs from your cluster and manually check the events logs(IPMI).Depending on your platform you will need to run different commands. Please...
View ArticleRe: ONTAP 8.3 Aggregate and volumes destroyed. Need to recover data.
Thanks for your reply. I'll check on lab and see results. With kind regards
View ArticleAudit log
A customer asked about Audit log.If I set Auditing in the Security Advanced tab of the window properties, where do the logs go?Do I create a shared volume so that the logs for each SVM or Share item...
View ArticleRe: broadcast domains
Hello, This means that the port has layer 2 reachability to its assigned broadcast domain and it also has layer 2 reachability to at least one other broadcast domain. - Examine the physical...
View ArticleRe: ONTAP 8.3 Aggregate and volumes destroyed. Need to recover data.
Just for closing this question, could undestroy de Aggr but actually is just showing under nodeshell.Netapp support team involvement is required to make it visible under clustershell and see after if...
View ArticleRe: Audit log
Hello, I believe you have already done the storage side configuration for this CIFS audit.https://kb.netapp.com/on-prem/ontap/da/NAS/NAS-KBs/How_to_set_up_NAS_auditing_in_ONTAP_9 You can run a “vserver...
View ArticleRe: Brocade warm reboot
Hi Alexey, To perform warm reboot, kindly use the command hareboot. Use this command to perform warm reboot in the switch-based systems. On chassis-based systems, this commandbehaves similar to the...
View ArticleRe: How to disable flow load sharing in two lif?
it should be this. There is no such feature to disable the SharesHow to Disable the CIFS shares temporarily - NetApp Knowledge Base
View ArticleRe: How to disable flow load sharing in two lif?
This doesn't seem to be relevant to what I'm talking about, I am referring to the Load Balance of LIF
View ArticleRe: Brocade warm reboot
Normally the clients/hosts will be having a physical multipath/redundant connection - same host connects to both the switches and has effective zoning available on both. So even when one switch is...
View ArticleRe: Brocade warm reboot
Yes, sure, there are two fabrics which are redundant but the point is not about a fabric being unavailable.As it's stated in the brocade documentation, the traffic is not disrupted during the warm...
View ArticleRe: Brocade warm reboot
Hi Alexey,There will be two partitions in the switches, primary and secondary partition.During the reboot secondary partition will get upgraded first and followed by the primary partition.It will be...
View ArticleRe: How to find a VMs (VMware, or Hyper-V) connected to which LUN. ?
Try this command, which can view the Serial NumberThen find the Serial Number on vmware
View ArticleRe: NFS to be mounted on windows server
You mount an export policy on windows that you want to add,You also need to enable access,how to enable you can see the official link...
View Article